PERBEDAAN INFORMASI ANATOMI ACL MRI KNEE JOINT T2W TSE DENGAN T2*GRE PADA POTONGAN SAGITAL DENGAN KASUS RUPTUR ACL DI INSTALASI RADIOLOGI RSUD PROVINSI NUSA TENGGARA BARAT

Authors

  • Mega Krisna Siagian Akademi Teknik Radiodiagnostik dan Radioterapi Bali
  • I Made Lana Prasetya Akademi Teknik Radiodiagnostik dan Radioterapi Bali
  • Bagus Gede Dharmawan Akademi Teknik Radiodiagnostik dan Radioterapi Bali

DOI:

https://doi.org/10.32670/ht.v2i3.2907

Keywords:

T2W TSE, T2*GRE, ACL, Prosedur Pemeriksaan Mri Knee Joint

Abstract

Protokol Survey_Full, Survey_Right, T2W_TSE_Tra, T2W_TSE_tra, T2W_TSE_Sag, T2W_SPIR, T1W_TSE_sag, T2W_TSE_sag, T2W_SPIR_cor sering digunakan untuk pemeriksaan MRI Knee Joint di RSUD Provinsi NTB, di Instalasi Radiologi RSUD Provinsi Nusa Tenggara Barat sekuens T2*GRE tidak menjadi sekuens rutin, sehingga penulis tertarik ingin membandingan hasil citra MRI Knee Joint T2W TSE dengan T2*GRE pada kasus ruptur ACL. Jenis penelitian ini adalah kuantitatif deskriptif. Penulis mengumpulkan data berupa 12 pasien hasil citra hasil radiograf dari pemeriksaan MRI Knee Joint terhadap 12 jumlah sampel pasien menggunakan sekuens T2W TSE dan T2*GRE Kemudian dari 12 hasil citra dilakukan penilaian berupa check list oleh responden yaitu 2 dokter radiolog. Data kemudian diolah dengan menggunakan spss. Hasil check list yang sudah diolah menggunakan spss, menurut hasil uji wilcoxon bahwa adanya perbedaan informasi anatomi ACL dengan sekuens T2W TSE dan T2*GRE sehingga diambil kesimpulan dengan hasil mean rank 2.00 jika sekuens T2W TSE lebih informatif dalam menilai anatomi ACL dari pada sekuens T2*GRE.

References

Cathherine Westbrook et al. MRI In Practice : Fifth Edition. Wiley-Blackwell. 2019;

Catherine Wastbrook et al. MRI In Practice : Fourth Edition,. Wiley-Blackwell. 2012;

Eunike Serfina, Heny Purnawati MA. No MRI ITU CRUNCHY. 2021.

GE Healtcare. Advantage Workstation for Diagnostic Imaging. Retrieved March 28. 2021;

Kingdom BSLU. Handbook of MRI Technique. 2014. four Edition.

Kingdom U. MRI in Practise, Blackwell Science Ltd : United Kingdom. 2012. Westbrook, C., and Kau.

Moeller, T.B & Reif E. MRI Parameters and Positioning,. Ger Georg Thieme Verlag. 2012;

No TitleTortora, J.G dan Derrickson, Bryan. 2017. Principle of Anatomy & Physiology.USA: Wiley. 2017;

Peter Nordback at el. Spatial distribution of RF-induced E-fields and implant heating in MRI,. Retrived at Maret. 2021;

Reliability UI. © IgE_Uji Interrater Reliability/Biostatistics/Nursing-Unklab 2016 Page 1. 2016;1–7.

Ryan, Stephanie, Nicholas, Michelle, dan Eustace S. Anatomy For Diagnostic Imaging Third Edition, Elsevier Limited. Toronto. 2013.

Studi P, Terapan S, Radiologi T, Jurusan P, Radiodiagnostik T, Politeknik R, et al. EVALUASI KUALITAS CITRA MRI KNEE JOINT POTONGAN SAGITAL PADA SEQUENCE T2 TURBO SPIN ECHO DAN T2 GRADIENT ECHO DI RUMAH SAKIT DISUSUN OLEH : FACHRIA ELFIRIANTI EVALUASI KUALITAS CITRA MRI KNEE JOINT POTONGAN SAGITAL PADA SEQUENCE T2 TURBO SPIN ECHO DAN T2 . 2019;

Westbrook C TJ. MRI in Practice Fifth Edition. Vol. 53, A. Vols. 1-737 p. 2019.

Downloads

Published

2023-01-24

How to Cite

Siagian, M. K. ., Prasetya, I. M. L. ., & Dharmawan, B. G. . (2023). PERBEDAAN INFORMASI ANATOMI ACL MRI KNEE JOINT T2W TSE DENGAN T2*GRE PADA POTONGAN SAGITAL DENGAN KASUS RUPTUR ACL DI INSTALASI RADIOLOGI RSUD PROVINSI NUSA TENGGARA BARAT. Humantech : Jurnal Ilmiah Multidisiplin Indonesia, 2(3), 381–392. https://doi.org/10.32670/ht.v2i3.2907